Reference: ITB/2020/15052
Description: Supply of Stationary Digital X-ray System for 2 working places to Ukraine.
X-ray system configuration:
- system based on floor-mounted
- X-ray diagnostics table
- X-ray stand
- X-ray high-voltage generator (power supply)
- X-ray emitter (generator)
- Flat Panel Detector in the table and in the stand
- Digital system of image processing
X-Ray Diagnostics table
- Size of the table surface - not less than 2010 х 820 mm
- Adjusting the height of the table above the floor - In the range of 500 to 800 mm
- Table load - not less than 220 kg
- Table side-to-side movement range - not less than 1000 mm
- The range of flat detector motorized lengthwise motion - not less than 500 mm
- Distance between the table surface and flat detector - not more than 70 mm
- Grid available
- Tube motorized vertical movement available
- Focus to floor distance - not less than from 350 to 2000 mm
- Horizontal and vertical auto-tracking function available
- Touch screen colour display interface for movement control - not less than 7.5 inch
X-ray stand
- Vertical movement range (align top) - In the range of 400 to 2000 mm
- Motorized vertical movement - not less than 1600 mm
- Grid available
- Vertical auto-tracking function available
X-ray radiation formation system
- Maximum generator power - not less than 50 kW
- Current adjustment range in radiography mode - not less than 10 – 600 mA
- Voltage adjustment range in radiography mode - not less than 40 – 150 kV
- Automatic exposure adjustment function available
- X-ray tube focal spots number - not less than 2
- Focal spot size - not more than 0.6 mm and 1.2 mm
- Anode X-ray tube heating capacity - not less than 600 000 thermal units
- Collimator with irradiation field illumination available
- Dose meter (DAP) available
Two Flat Panel Detectors: in the Table (1) and in the stand (1)
- Input field size - (43 × 43) ± 1 cm
- Image Matrix - not less than 2800×2800
- Pixel size - not more than 150 microns
- DQE magnitude at 0 pairs of lines/cm - not less than 60%
Digital System of image processing
- Saving images: hard disk capacity not less than 500 GB in mirror-image mode
- Laboratory Assistant Workstation
- Image postprocessing mode with the ability to:
- Adjust brightness
- Use compensational filters
- Rotate images
- Invert images
- Increase (magnify)
- Annotate
- DICOM Network connection: Store, Print
- Touch screen (sensor) remote control for exposure settings
- LCD monitor with a diagonal of not less than 19": to view current images
- Ability to record data reports on CD and DVD using DICOM file viewer program
Accessories and other equipment
- Patient radiation exposure measuring device
- Power distribution panel
- UPS (Uninterrupted power supply) for digital system
- Protective lead glass, non-framed - not less than 1000 x 900 mm
Maximum weight of the whole system (the installation premises can not sustain heavier weight) - not more than 1500kg