Print

41-754 Enel La Spezia conden. treat. R
Details
Locations:Italy
Start Date:Unknown
End Date:Dec 31, 2007
Sectors: Water & Sanitation
Description
KEY STAFF
Project Director P. Lucchi
Project Manager F. Matteucci
Process Manager A. Trezzi
Chief Designer A. Spada
Quality Controller A. Trezzi
PROCESS
Water to be treated Condensate
Total Design Capacity Regeneration of 2750 lt of carbonic resin and 3500 of anionic resin
Number of lines N° 1 (regeneration in separate vessels A + C)
Guaranteed TDS Correct regeneration and running
Resins Type Purolite C150+LH / Purolite a 500 TL
Regeneration System Counter Flow
Regenerants Type HCl 30 ÷ 33% + NaOH 30%
Regenerators Material / Lining Carbon steel 516 GR. 70 rubber lined thk 3 mm.
Scope of work
Turn key delivery
Notes:
Plant delivered in 6-7 months in accordance with contractual schedule
Site services performed for supervision and commissioning